HomeBench InstrumentsInstrumentation ModulesSmall Instrumentation ModulesSRS SIM921 AC Resistance Bridge

SRS SIM921 AC Resistance Bridge

SRS SIM921 AC Resistance Bridge
 
Click for larger image
 
SRS SIM921 AC Resistance Bridge
 
 
 
 
SRS SIM921 AC Resistance Bridge
 
 
 
 

 

 

 

Ask for quotation


 




 

captcha

 
  • Accurate millikelvin thermometry
  • Microvolt/picoamp excitation
  • Measurements from 1 mΩ to 100 MΩ
  • Variable excitation from 2 Hz to 60 Hz
  • Linearized analog output
  • Resistance, temperature and phase

The SIM921 AC Resistance Bridge is a precision, low-noise instrument designed for cryogenic thermometry applications. With excitation power below 100 aW, thermistors and other resistive samples can be measured at temperatures below 50 mK with negligible self-heating errors.

 

Measuring Resistance

The SIM921 measures resistance using a four-wire circuit, eliminating the direct effect of lead resistance on the result. Thermal EMFs and amplifier offset drifts are avoided by using an AC excitation current source.

 

The excitation frequency can be adjusted from 2 Hz to 60 Hz, either from the front panel or over the computer interface. This flexibility allows the user to operate at a synchronous sub-harmonic of the power line frequency (such as 15 Hz/12.5 Hz) or at some incommensurate frequency, depending on requirements.

Multiple SIM921s can be operated at different frequencies in the same experimental set-up without risking in-band crosstalk. Also, for very high impedance measurements, the variable frequency makes it possible to probe any capacitive effects in the resistance result.

Excitations are sinusoidal, eliminating the high-frequency harmonic content associated with square wave excitations.  

 

The actual determination of resistance is achieved ratiometrically, passing the selected excitation current through both an internal, high-stability reference resistor as well as the user's device under measurement. An internal autocal is available to calibrate the two arms of the ratio readout for greater accuracy.

 


 
Download datasheet »
 
 
 
 