Schlöder CDG 6000 Conducted disturbance test generator 150 kHz – 230 MHz

Schlöder CDG 6000 Conducted disturbance test generator 150 kHz – 230 MHz
 
Klicka på bild för att förstora
 
 
 
 
 
 
 
 
 

Radiated disturbances from external sources show usually longer wave lengths than the dimensions of a single component in an installation.

Although there exist disturbances, caused by induced RF interference in power and signal lines. The dimensions of the lines corresponds usually several wave lengths and act therefore as antennas.


The EN 61000-4-6 describes a test set up to simulate the induction without a complex set up with antennas, field measurement equipment and highly screen test chambers.

Via coupling networks and coupling clamp's sine waves are induces directly into power and signal lines. The EUT keeps its usual place in the installation; the complete unit can be tested in its function.

 

>>Read more!

 

 

 

Begär offert

 




 

captcha

 

  • Frequency range 150 KHz to 230 MHz
  • CDG 6000-75 with 75 W amplifier
  • Output voltage (CDN or coupling clamp)
  • CDG 6000 I max. 15 V with 80% AM, (25W amplifier)
  • CDG 6000-75 II max. 40 V with 80% AM, (75W amplifier)
  • Computer-based system (controlled by USB).
    • - Unequalled flexibility, easy operation, fully expandable for future standards modification.
    • - Easy integration in automated measurement and test systems
  • Self calibration of the test system
  • RF-generator, amplifier and RF-voltmeter may as well be used as stand-alone devices
  • Connections:
    • - External multimeter for monitoring EUT
    • - EUT fail - TTL/CMOS compatible input (stops running application or sets a frequency mark)
    • - External modulation signal
  • Calibration of coupling / decoupling devices is performed automatically
  • A mounting plate with 50/150 Ohm passage and a calibration adaptor are necessary, depending of the used CDN.
  • Extensive additions like attenuators, calibration kits, etc. deliverable

The test generator generates interferences as defined in IEC / EN 61000-4-6 - Immunity to conducted disturbances, induced by radio-frequency fields.

 

The standard described a test setup, in which can influence these high-frequency interferences without a complicated structure with antennas, field instrumentation and shielded rooms on a EUT.

 

Via coupling networks and coupling clamp's sine waves are induced directly into power and signal lines.

The EUT keeps its usual place in the installation; the complete unit can be tested in its function.

 

 

 
Ladda ner datablad »
 
Ladda ner manual »
 
Ladda ner extra dokument »
 

Relaterade produkter

Schlöder CDN-EMCL, EM clamp for immunity tests acc. EN 61000-4-6
The preferred coupling and decoupling devices are the CDNs, for reasons of test reproducibility and ...
Offereras
Schlöder Coupling-/Decoupling Network for IEC 61000-4-6
Coupling- /decoupling networks (CDN) for immunity tests to conducted disturbances induced by radio f...
Offereras
 